<?xml version="1.0" encoding="UTF-8" ?>
<!-- Created from PDF via Acrobat SaveAsXML -->
<!-- Mapping Table version: 28-February-2003 -->
<TaggedPDF-doc>
<?xpacket begin='﻿' id='W5M0MpCehiHzreSzNTczkc9d'?>
<?xpacket begin="﻿" id="W5M0MpCehiHzreSzNTczkc9d"?>
<x:xmpmeta xmlns:x="adobe:ns:meta/" x:xmptk="Adobe XMP Core 9.1-c001 79.675d0f7, 2023/06/11-19:21:16        ">
   <rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#">
      <rdf:Description rdf:about=""
            xmlns:xmp="http://ns.adobe.com/xap/1.0/"
            xmlns:pdf="http://ns.adobe.com/pdf/1.3/"
            xmlns:dc="http://purl.org/dc/elements/1.1/">
         <xmp:ModifyDate>2025-08-07T11:10:22Z</xmp:ModifyDate>
         <pdf:Producer>iLovePDF</pdf:Producer>
         <dc:format>xml</dc:format>
      </rdf:Description>
   </rdf:RDF>
</x:xmpmeta>
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                                                                                                    
                           
<?xpacket end="w"?>
<?xpacket end='r'?>

<Part>
<H1>DENTAL MATERIALS </H1>

<Link>
<P>COMPARATIVE EVALUATION OF ACCURACY/ACCURACY OF ELASTOMERIC CONDENSATION AND ADDITION IMPRESSIONING MATERIALS </P>

<P>Vlad Gabriel Vasilescu1a 
<Link><Figure>

<ImageData src="images/Article_11_1-2_2_img_0.jpg"/>
</Figure>
</Link>
, Irini Qirici2b , Maria-Emilia Constantin1c* 
<Link><Figure>

<ImageData src="images/Article_11_1-2_2_img_0.jpg"/>
</Figure>
</Link>
, Marian Miculescu3d 
<Link><Figure>

<ImageData src="images/Article_11_1-2_2_img_0.jpg"/>
</Figure>
</Link>
, Florin-Eugen Constatinescu4e 
<Link><Figure>

<ImageData src="images/Article_11_1-2_2_img_0.jpg"/>
</Figure>
</Link>
, Lucian-Toma Ciocan1f </P>

<Link>
<Sect><Figure>

<ImageData src="images/Article_11_1-2_2_img_0.jpg"/>
</Figure>
</Sect>
</Link>

<P>1 Faculty of Dentistry, “Carol Davila” Medicine and Pharmacy University, 37, Dionisie Lupu Str., District 2, 020021 Bucharest, Romania 2 Faculty of Medical Engineering, University “Politehnica” of Bucharest, 1-7, Gheorghe Polizu Str., Corp F, District 1, 011061 Bucharest, Romania 3 Faculty of Material Science and Engineering, University “Politehnica” of Bucharest, 313, Splaiul Independentei, corp JA 104-106, District 6, 060042 Bucharest, Romania 4 Doctoral School, Faculty of Dentistry, “Carol Davila” University of Medicine and Pharmacy, 37, Dionisie Lupu Str., District 2, 020021 Bucharest, Romania </P>

<P>a DDS, PhD, Assistant Professor; e-mail: 
<Link>vlad.vasilescu@umfcd.ro</Link>
; ORCIDiD: 
<Link>https://orcid.org/0000-0001-6251-833X </Link>
b BioEng, PhD; e-mail: 
<Link>iriniqirici@yahoo.com </Link>
c student;e-mail:
<Link>
<Link>maria-emilia.</Link>
constantin0720@stud.umfcd.ro</Link>
;ORCIDiD:
<Link> https://orcid.org/0009-0004-6242-4615 </Link>
d Eng, PhD, Professor; e-mail: 
<Link>marian.miculescu@upb.ro</Link>
; ORCIDiD: 
<Link>https://orcid.org/0000-0002-2723-6713 </Link>
e DDS, MSc.Neur.Orth; e-mail: 
<Link>florin-eugen.constantinescu@drd.umfcd.ro</Link>
; ORCIDiD: 
<Link>https://orcid.org/0000-0002-9425-0291 </Link>
f DMD, MD, PhD, Associate Professor; e-mail: 
<Link>lucian.ciocan@umfcd.ro</Link>
; ORCIDiD: 
<Link>https://orcid.org/0000-0002-0329-5102 </Link>
</P>
</Link>

<P><Figure>

<ImageData src="images/Article_11_1-2_2_img_1.jpg"/>
</Figure>

<Link>https://doi.org/10.25241/stomaeduj.2024.11(1-2).art.</Link>
2</P>

<P>ABSTRACT </P>

<P>Introduction The scientific selection of dental materials in modern dentistry requires the evaluation of their characteristics based on physical, chemical, and mechanical tests, in order to assess their typical properties. Comparative analysis of material characteristics for  the right option in a specific application has demonstrated over time a close link between the clinical success of materials and certain of their properties. Methodology The purpose of the study is to evaluate the basic characteristics, namely fidelity and dimensional stability, of some elastomeric addition and condensation materials. The experimental samples made of siloxane polyvinyl with different fluidity (medium and high) were placed in a fidelity test device (test block, mold), according to SR EN 4823:2002 standard, two samples of each, one being condensation and the other addition. Results The study of the adaptation mode and the characteristics regarding the impressioning accuracy was carried out by three methods of analysis, namely: stereomicroscopy, photolithography and digital scanning. Stereomicroscopy showed that the material adapted well to the mold surface, but showed irregularities. Photolithography indicated that the material has good fidelity, even if some of the samples are less accurate, and digital scanning reinforces the idea that the materials used in this study show good fidelity. Conclusion The results obtained are satisfactory for the experimental samples of addition and condensation polyvinyl siloxane, all the more so as their fluidity is higher and the comparative analysis of the results has provided conclusive information on the properties suitable for accurate impressioning. </P>

<P>KEYWORDS </P>

<P>Original Articles </P>

<P>Dental Impression; Fidelity, Accuracy, Dimensional Accuracy, Addition and Condensation Polyvinyl Siloxane. </P>

<P>1. INTRODUCTION of minimal pressure, recording all morphological details of the prosthetic field without deforming its </P>

<P>The selection of impression materials in dentistry is based on their characteristics [1,2,3,4,5,6,7,8] reliefs, dimensional stability, or a characteristic of </P>

<P>and mainly takes into account the impressioning the material that ensures the faithful preservation of techniques used [9,10,11] and the particularities of the negative image of the prosthetic field from the the prosthetic field. Among these characteristics, moment of disinsertion of the imprint from the oral </P>

<P>of particular practical importance are: fidelity or cavity until after the final grip of the material,  the time accuracy with which impression materials manage of socket, or the characteristic that must satisfy the to reproduce the finest details of the prosthetic clinical requirements according to the particularities field, plasticity, defined by  the ability of the material of each impressioning technique [12,13,14,15,16], to be deformed and modeled under the action compatibility with model materials. </P>

<P><Figure>

<ImageData src="images/Article_11_1-2_2_img_2.jpg"/>
</Figure>
OPEN ACCESS This is an Open Access article under the CC BY-NC 4.0 license. Peer-Reviewed Article Citation: Vasilescu VG, Qirici I, Constantin ME, et al. Comparative accuracy evaluation of condensing and addition impression materials.  Stoma Edu J. 2024;11(1-2):35-41. Received: December 17, 2023;  Revised: March 03, 2024;  Accepted: March 25, 2024; Published: March 29, 2024. *Corresponding author: Maria-Emilia Constantin, Prosthetics Technology Department, Faculty of Dentistry, &quot;Carol Davila&quot; University of Medicine and Pharmacy, 4–6, Eforiei Str., 4th Floor, Off. 31, District 5, 050037 Bucharest, Romania; Phone +40724–902 400, Fax +4021–313 53 77; e-mail: 
<Link>mariaconstantin1810@gmail.com </Link>
Copyright: © 2022 the Editorial Council for the Stomatology Edu Journal. </P>

<Sect>
<P>35-41 </P>
</Sect>

<P>35 </P>

<Sect/>

<P>Original Articles </P>

<P>Fidelity and dimensional stability are two essential physical characteristics characterizing the performance of synthetic elastomers as impression materials [17,18,19] as a result of remarkable advances in synthetic polymer chemistry. These characteristics express the ability of silicone and polyetheric impression materials to reproduce the surface details of dental preparations in a very precise way and to maintain these details over a period of time sufficient to allow precise patterns to be cast under optimal conditions. Factors affecting the fidelity and dimensional stability of elastomeric impression materials [20,21] include changes that occur during polymerization, such as volumetric reductions, loss of alcoholic groups, which cause contractions and, last but not least, temperature, disinfectants and impressioning techniques. Synthetic elastomers (polysulfides, polysiloxane polyethers), according to international norms (ISO) are classified as follows: type I - putty (Putty); type II - with increased viscosity for preliminary impressions (Heavy bodied); type III </P>

<P>- medium viscosity for a wide range of impressions (Regular); type IV-  low viscosity (fluids) for syringe injection techniques (Light bodied). Silicone elastomers (silicones) are compounds containing organic groups, one or more of which are covalently bonded to a silicon atom [22,23,24]. Silicones are sold in three viscosity variants (high, medium and low), each in a two-component system (base and catalyst). The base is packaged in tubes (silicones of medium and fluid consistency) or in cartons (those with chitous consistency), and the catalyst (activator) in vials, when in liquid form, or in tubes when presented as a paste. Silicone elastomers used for impressioning are obtained either by polycondensation reactions or by polyaddition reactions [25,26]. The addition silicones are composed of base paste (polyvinylsiloxane) and accelerator paste (polyxyloxane with terminal vinyl group, organometallic catalyst – chloroplatinic acid). Condensation silicones are composed of base paste (polydimethylsiloxane, inert inorganic mass that ensures the necessary viscosity and rigidity consists of pyrolytic silica and titanium dioxide (plasticizer)) and accelerator paste (tin octotate, ethyl orthosilicate, sometimes chromium oxide or palladium metal particles with the role of capturing hydrogen that is not beneficial to the footprint surface). Siloxane polyvinyl materials are an improvement in condensation silicones. Both are based on polydimethyl siloxane polymer, but their plug processes are distinct due to the presence of different terminal groups. In the basic substance, a polymer containing silane terminal groups called polymethyl hydrogen siloxane copolymer is present, which has a low molecular weight. Vinyl polydimethyl siloxane is present in the accelerator substance, although it comprises vinyl terminal groups, and this polymer has a moderately low molecular weight. As a homogeneous metallic complex catalyst, chloroplatinic acid is also a component of the accelerator material. When silane and vinyl groups are combined, an addition process takes place. The properties of siloxane polyvinyl vary greatly in terms of viscosity, working and grip time, breaking energy, elastic recovery and deformation, dimensional stability, creep conformity, radiopacity, etc. [27]. It is common when fluid silicone, with low viscosity, is used in the second time in impressioning techniques, after using chitous material. Each material has its own advantages and disadvantages, and its choice is made based on factors such as accuracy, ease of use and patient comfort [28]. They must demonstrate excellent detail reproduction, good tear resistance, be biocompatible and non-toxic, etc. The evaluation of basic characteristics such as fidelity and dimensional stability, but also the comparative analysis of the results obtained when evaluating them by the three study methods, demonstrates the possibility of successful use of elastomeric addition and condensation materials [30, 37, 38, 39]. </P>

<Sect>
<P>2. MATERIALS AND METHODS </P>

<P>The material used in the experiments is polyvinyl siloxane of different fluidities. For each high and medium fluidity, two samples were obtained, one condensation and the other addition. </P>

<P>2.1. Preparation of test samples </P>

<L>
<LI>
<Lbl>a) </Lbl>

<LBody>The medium fluidity condensation polyvinyl siloxane sample is prepared from Zhermack Zetaplus chitous silicone and Zhermack catalyst, indurent (induced) gel. The two components were thoroughly mixed to remove air bubbles (mixing time about 30 seconds) until a homogeneous, grey mixture was obtained (Fig. 1a). </LBody>
</LI>

<LI>
<Lbl>b) </Lbl>

<LBody>The medium fluidity addition polyvinyl siloxane sample was prepared from Zhermack elite HD+ chitous silicone and a Zhermack elite HD+ catalyst by manually mixing the two components to eliminate air bubbles for about 30 seconds. A homogeneous yellow-orange material  was obtained (Fig. 1b). </LBody>
</LI>
</L>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_3.jpg"/>
</Figure>

<P>Figure 1a. Siloxane polyvinyl samples: a. condensation with medium fluidity. Figure 1b. Siloxane polyvinyl samples: b. addition with medium fluidity. </P>

<L>
<LI>
<Lbl>c) </Lbl>

<LBody>The high fluidity condensation polyvinyl siloxane sample was prepared from Lascod silicone Silaxyl Light body = fluid consciousness, together with a universal catalyst, Coltene Speedex activator. Mixing these two materials was done on waxed paper, by mixing vigorously with a spatula and pressing on waxed paper to remove air bubbles. The mixing time is approximately 30 seconds until a homogeneous blue material is obtained (Fig. 2a). </LBody>
</LI>

<LI>
<Lbl>d) </Lbl>

<LBody>The high-fluidity addition polyvinyl siloxane sample was prepared from a Zhermack elite HD+ super light body consistency. A pink sample of suitable consistency (neither hard nor soft) was obtained (Fig. 2b). </LBody>
</LI>
</L>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_4.jpg"/>
</Figure>

<P>Figure 2a. Siloxane polyvinyl samples: a. High fluidity condensation. Figure 2b. Siloxane polyvinyl samples: b. high fluidity addition. </P>
</Sect>

<P>The four samples of different colors, respectively of the four impression materials, were placed in a fidelity testing device (a stainless steel test block) in accordance with SR EN 4823:2002 standard, (Fig. 3) for the evaluation of elastomeric impression materials. </P>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_5.jpg"/>
</Figure>

<P>Figure 3. The three components of the test piece. </P>

<P>The preparation of the samples consists in preparing the paste from the studied impression material, placing it in the mold (standard) and evenly distributing throughout the mold mass to eliminate gaps and air bubbles. After about 3-5 minutes the sample is subjected to analysis. </P>

<P>2.2. Methods for analysing experimental samples </P>

<P>The study of adaptation mode and impressioning accuracy characteristics was carried out by three methods of analysis: stereomicroscopy, photolithography and digital scanning. </P>

<P>2.2.1. Stereomicroscopy analysis </P>

<P>For this experimental study, the Nikon SMZ1270 stereomicroscope was used with a wide range of accessories (trinocular tubes and diascopic lighting holders with thin LEDs), which has a number of advantages, such as zoom ratio, the highest in its class, and high-resolution viewing of 640LP/mm. </P>

<P>2.2.2. Analysis by photolithography</P>

<P> Photolithography has the ability to manipulate the geometry of features with very good precision and can produce patterns with very small characteristics, down to several tens of nanometers. </P>

<P>2.2.3. Analysis by digital CAD/CAM scanning </P>

<P>The study used PlanScan Lab's PlanScan Lab scanner. Gypsum patterns and impressions can be scanned quickly and accurately using this desktop scanner, with a wide range of applications including full arch bridges, implant bars and crowns. </P>

<P>3. RESULTS </P>

<P>The results regarding the fidelity and dimensional stability were obtained, recorded and studied, expressed by the dimensions (widths and length) of the three parallel grooves on the standard (mold) and on the experimental samples. The results of the stereomicroscopy analysis  are shown in the images below, which shows the average of the width values of the three parallel grooves on the five samples. The trenches have different widths, trench 1 is the thickest, trench 2 is medium width and trench 3 the thinnest. </P>

<P>Table 1. Average furrow width measurements from five different areas. </P>

<P>Original Articles </P>

<Table>
<TR>
<TH>The width of the grooves </TH>

<TH>Standard </TH>

<TH>Zhermack Zetaplus putty (gray) </TH>

<TH>Zhermack elite HD+ putty (yellow) </TH>

<TH>Lascod Silaxil light body (blue ) </TH>

<TH>Zhermack elite HD+ light body (violet) </TH>
</TR>

<TR>
<TD>Groove 1 </TD>

<TD>187.80μm </TD>

<TD>1.60mm </TD>

<TD>1.21 mm </TD>

<TD>181.34μm </TD>

<TD>2.30 mm </TD>
</TR>

<TR>
<TD>Groove 2 </TD>

<TD>182.63μm </TD>

<TD>167.13μm </TD>

<TD>656.36μm </TD>

<TD>149.47μm </TD>

<TD>2.09 mm </TD>
</TR>

<TR>
<TD>Groove 3 </TD>

<TD>169.71μm </TD>

<TD>103.81μm </TD>

<TD>161.96μm </TD>

<TD>123.62μm </TD>

<TD>1.39 mm </TD>
</TR>
</Table>

<P>3.1. Results of stereomicroscopy analysis </P>

<P>Also with the help of the stereomicroscope, the length of the trench was measured on each sample, the measurement results are shown in the images below (Fig. 4ab-5ab) and in Table 2. </P>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_6.jpg"/>
</Figure>

<P>Figure 4a. Ditch length a. on metal piece. </P>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_7.jpg"/>
</Figure>

<P>Figure 4b. Ditch length b. on Zhermack zetaplus putty sample. </P>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_8.jpg"/>
</Figure>

<P>Figure5a. Ditch length a. on Zhermack elite HD+ putty sample. </P>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_9.jpg"/>
</Figure>

<P>Figure 5b. Ditch length b. on the Lascod Silaxil light body sample. Table 2. The three components of the test piece. </P>

<Table>
<TR>
<TH>Groove depth </TH>

<TH>Mold </TH>

<TH>Gray sample </TH>

<TH>Yellow sample </TH>

<TH>Blue sample </TH>

<TH>Sample purple </TH>
</TR>

<TR>
<TD>Value </TD>

<TD>24.895 mm </TD>

<TD>24.844 mm </TD>

<TD>25.114 mm </TD>

<TD>24.834 mm </TD>

<TD>24.849 mm </TD>
</TR>
</Table>

<P>3.2. Results of photolithography analysis </P>

<P>The images below (Fig. 6a-6b) present the experimental results for each sample in which two profiles were recorded, one representing the length of the sample, and the other the depths of the three grooves. For this analysis, in addition to photolithography, advanced metrology (Metrology </P>

<P>4.0 Analysis 9.1.9957) was used to study surface roundness and to measure important structural factors such as size, depth, geometry and surface quality. </P>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_10.jpg"/>
</Figure>

<P>Figure 6a. Profile 1 / mold length. </P>

<Sect>
<P>35-41 </P>
</Sect>

<P>37 </P>

<Sect>
<P>Table 6. The groove length values from the scan of the five samples. </P>
</Sect>

<P>Original Articles </P>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_11.jpg"/>
</Figure>

<Sect>
<P>Figure 6b. Profile 2 / depths of mold grooves. </P>

<P>3.3. Analysis results from digital scanning </P>
</Sect>

<P>The images below (Fig. 7a-7b) show the results of the analysis from the digital scan. These images show the samples in 3D CAD/CAM plane, but also the measurements made for the length of the trench. The samples were placed on the scanner stand, scanned, and then converted into 3D images. Table 6 shows the lengths for each of the 5 samples. </P>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_12.jpg"/>
</Figure>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_13.jpg"/>

<Caption>
<P>Figure 10. Profile 1 / sample length of medium fluidity condensation polyvinyl siloxane (grey material). </P>
</Caption>
</Figure>

<Sect>
<Table>
<TR>
<TH>Groove depth </TH>

<TH>Mold </TH>

<TH>Gray sample </TH>

<TH>Yellow sample </TH>

<TH>Blue sample </TH>

<TH>Sample purple </TH>
</TR>

<TR>
<TD>Groove 1 </TD>

<TD>0.3366 mm </TD>

<TD>0.4062 mm </TD>

<TD>0.3700 mm </TD>

<TD>0.3791 mm </TD>

<TD>0.3803 mm </TD>
</TR>

<TR>
<TD>Groove 2 </TD>

<TD>0.2120 mm </TD>

<TD>0.1404 mm </TD>

<TD>0.2080 mm </TD>

<TD>0.0001 mm </TD>

<TD>0.1858 mm </TD>
</TR>

<TR>
<TD>Groove 3 </TD>

<TD>0.2480 mm </TD>

<TD>0.1890 mm </TD>

<TD>0.2970 mm </TD>

<TD>0.3297 mm </TD>

<TD>0.2344 mm </TD>
</TR>
</Table>

<P>4. DISCUSSION </P>

<P>The stereomicroscpie analysis highlighted the impressioning characteristics of the experimental samples by evaluating the size values (width and length) of the three parallel grooves on the five experimental samples and the differences recorded from those on the block (standard) test. From the measured width values/table 1 it follows that the three parallel grooves (1, 2 and 3) are uneven, starting with the first groove where there is a large difference between the samples and the block test.  More accurate results in width with the standard were obtained in the sample of addition polyvinyl siloxane with medium fluidity (yellow). Trench length measurements (Tab. 2) show very accurate values between samples. The medium fluidity addition polyvinyl siloxane sample has a slightly lower value, and the high fluidity condensation polyvinyl siloxane sample (blue) has values close to the block test length. Compared to the other samples, high-fluidity condensation polyvinyl siloxane has the values closest to standard. Having greater fluidity means that it also has a large grip contraction, which leads to high dimensional stability, but distortions can occur if the plug contraction is greater than it should be. When assessing the shrinkage of the socket, it is observed how much the material has entered the trench (fidelity) and how much it has contracted between the edges (stability). The photolithography analysis that records the profiles of the experimental samples assessing the length and depth of the three grooves revealed that the samples have the same diameter as the mold (profile 1), with very small differences between them, of 0.003-0.100 mm (Tab. 3). Trench length measurements show similar values for all of them, namely 25 mm. Compared to the trench length in the mold, which is 24.9193 mm, samples show that the material is adapted to the mold, </P>

<P>i.e. it contracted well between the edges of the mold. Profile 2 shows the depths of the trenches, measured values on the standard sample and on the experimental samples. The values in the mold range from 0.1424 mm (trench 1) and 0.0937 (trench 3) to 0.0560 mm (trench 2), but it is noticeable that the material did not insinuate itself very well in all cases (Tab. 4). </P>

<P>Table 3. Groove length values on the five samples. </P>

<Table>
<TR>
<TH>The width of the grooves </TH>

<TH>Standard </TH>

<TH>Zhermack Zetaplus putty (gray) </TH>

<TH>Zhermack elite HD+ putty (yellow) </TH>

<TH>Lascod Silaxil light body (blue ) </TH>

<TH>Zhermack elite HD+ light body (violet) </TH>
</TR>

<TR>
<TD>Value 1 </TD>

<TD>25.066 mm </TD>

<TD>25.677 mm </TD>

<TD>23.184 mm </TD>

<TD>25.109 mm </TD>

<TD>25.218 mm </TD>
</TR>
</Table>

<P>Table 4. These are the groove depth values for the five samples. </P>
</Sect>

<Table>
<Caption>
<P>Figure 11. Profile 2 / depth of grooves of medium fluidity condensation polyvinyl siloxane sample (grey material). </P>
</Caption>

<TR>
<TH>Length of the groove </TH>

<TH>Groove depth </TH>

<TH>Mold </TH>

<TH>Gray sample </TH>

<TH>Yellow sample </TH>

<TH>Blue sample </TH>
</TR>

<TR>
<TD>Value </TD>

<TD>24.9193 mm </TD>

<TD>25.0957 mm </TD>

<TD>25.3846 mm </TD>

<TD>25.3893 mm </TD>

<TD>25.5502 mm </TD>
</TR>
</Table>

<P>Knowing that impression materials usually evince shrinkage of the socket, with this method of analysis, one can see how much the material has entered the trench (fidelity), but also how much it has contracted between the edges (stability). It is visible, both from the graphs and from the tabulated values, that the fluidity of the material influenced its adaptation, trench 2 being almost invisible, and in the case of the addition polyvinyl siloxane sample with medium fluidity (yellow) the material did not even enter the trench. On the high fluidity addition polyvinyl siloxane sample (violet) all trench depths are observed, the measurement values being even closer to those in the mold. If we consider the widths of the grooves, the mold shows the following values: 0.3366 mm (1), 0.2120 mm (2), 0.2480 (3), and the samples have different values from each other, but are close to those measured in the mold (Tab. 5). </P>

<P>Table 5. Groove width values on the five samples. </P>

<Table>
<TR>
<TH>Groove depth </TH>

<TH>Mold </TH>

<TH>Gray sample </TH>

<TH>Yellow sample </TH>

<TH>Blue sample </TH>

<TH>Sample purple </TH>
</TR>

<TR>
<TD>Groove 1 </TD>

<TD>0.1424 mm </TD>

<TD>0.1200 mm </TD>

<TD>0.1280 mm </TD>

<TD>0.1170 mm </TD>

<TD>0.1711 mm </TD>
</TR>

<TR>
<TD>Groove 2 </TD>

<TD>0.0560 mm </TD>

<TD>0.0100 mm </TD>

<TD>0.0260 mm </TD>

<TD>0.0098 mm </TD>

<TD>0.0230 mm </TD>
</TR>

<TR>
<TD>Groove 3 </TD>

<TD>0.0937 mm </TD>

<TD>0.0370 mm </TD>

<TD>0.0611 mm </TD>

<TD>0.0624 mm </TD>

<TD>0.0780 mm </TD>
</TR>
</Table>

<P>Here, too, the experimental sample of addition polyvinyl siloxane with high fluidity is the one with values much closer to the mold. We can also appreciate that the medium fluidity condensation polyvinyl siloxane sample (gray sample) did not adapt very well to the mold, and the high fluidity addition polyvinyl siloxane sample (purple sample) has better fidelity. The digital scanning analysis method confirms the previous results and highlights once again that these materials have adapted well with the respective mold. The differences between the values are very small. Only the medium-fluidity addition polyvinyl siloxane sample has a longer length than the other samples. What is important, however, is that the shape of the grooves in the samples is similar to the mold (scan images). This means that the materials have good stability and entered the trench very well, the sample closest to the mold was the purple sample, made of addition polyvinyl siloxane with wrinkled fluidity. </P>

<P>REFERENCES </P>

<L>
<LI>
<Lbl>1.</Lbl>

<LBody> Connor RA, Dorfman J, Ring ME, Kamen S. Dentistry. Encyclopedia Britannica, December 28, 2023. Available from: 
<Link>https://www.britannica.com/science/dentistry</Link>
. </LBody>
</LI>

<L>
<LI>
<Lbl>2.</Lbl>

<LBody> Ratner BD, Hoffman AS, Schoen FJ, Lemons JE. Biomaterials Science: An Introduction to Materials in Medicine. Third Edition, Elsevier Academic Press: New York, NY, USA; 2013. </LBody>
</LI>

<LI>
<Link>Full text links </Link>

<Link>Google Scholar </Link>
</LI>
</L>

<LI>
<Lbl>3.</Lbl>

<LBody> Martinez V. Introduction to dental materials. Accessed: Jun. 12, 2023. [Online]. Available from: 
<Link>https://www.academia. </Link>

<Link>edu/50756970/Introduction_to_Dental_Materials </Link>
</LBody>
</LI>

<L>
<LI>
<Lbl>4.</Lbl>

<LBody> Sakaguchi RL, Powers JM. Craig's Restorative Dental Materials-E-Book. Elsevier Health Sciences; 2011. </LBody>
</LI>

<LI>
<Link>Full text links </Link>

<Link>Google Scholar </Link>
</LI>
</L>

<LI>
<Lbl>5.</Lbl>

<LBody> Cleveland Clinic. Dental impressions: definition, purpose &amp; procedure [Online]. Accessed Apr. 21, 2023. Available from: </LBody>
</LI>
</L>

<P>
<Link>https://my.clevelandclinic.org/health/diagnostics/22671-den</Link>

<Link>tal-impressions </Link>
</P>

<P>[6. Gupta R, Brizuela M. Dental Impression Materials. 2023 Mar 19. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2024. </P>

<P>5. CONCLUSION </P>

<P>The precision with which the impression material records tissue details will determine the quality and how well the restoration or final prosthesis fits. This accuracy of the impression material depends both on its properties and on the techniques for obtaining the impression. The study meets the proposed objective, which is to evaluate the basic characteristics, namely fidelity and dimensional stability of elastomeric addition and condensation materials with different fluidity. Experimental research is aimed at studying the impressioning accuracy of polyvinyl siloxane as an impression material. The comparative analysis of the experimental results on how to adapt and the accuracy of impressioning by the three study methods (stereomicroscopy, photolithography and digital scanning) highlighted the following important aspects with practical utility: </P>

<P>- photolithography is the method of analysis that has the best accuracy; </P>

<P>-elastomeric imprint materials with high fluidity reproduce details better compared to those with increased consistency; </P>

<L>
<LI>
<Lbl>-</Lbl>

<LBody> regardless of consistency (fluid or viscous) addition silicones are more dimensionally stable than condensation silicones; </LBody>
</LI>

<LI>
<Lbl>-</Lbl>

<LBody> the highest fidelity (accuracy of reproduction of details) was demonstrated in experiments by addition silicone (Elite HD superlight body), probably also due to the high fluidity found during application; The results of the study shall also provide useful information on methods of study and analysis in establishing the essential characteristics of basic impression materials in order to obtain an accurate impression. </LBody>
</LI>
</L>

<P>AUTHOR CONTRIBUTIONS </P>

<P>All authors have read and agreed to the published version of the manuscript. </P>

<P>FUNDING </P>

<P>This research received no external funding. </P>

<P>DATA AVAILABILITY STATEMENT </P>

<P>The data presented in this study are available on request from the corresponding author. The data are not publicly available due to privacy reasons. </P>

<P>CONFLICT OF INTEREST </P>

<P>Authors declare that there is no conflict of interests. </P>

<L>
<L>
<LI>
<Lbl>7.</Lbl>

<LBody> Bhakta S, Vere J, Calder I, et al. Impressions in implant dentistry. Br Dent J. 2011 Oct 21;211(8):361-367. doi: 10.1038/ sj.bdj.2011.862. </LBody>
</LI>

<LI>
<Link>Full text links </Link>

<Link>CrossRef </Link>

<Link>PubMed </Link>

<Link>Google Scholar </Link>

<Link>WoS </Link>
</LI>
</L>

<LI>
<Lbl>8. </Lbl>

<LBody>The difference between impression materials [Online]. Accessed Jun. 13, 2023. Available from: 
<Link>https://www.dental</Link>

<Link>nursenetwork.com/news/dental-nursing-library/1073-the-diffe</Link>

<Link>rence-between-impression-materials.html </Link>
</LBody>
</LI>

<L>
<LI>
<Lbl>9.</Lbl>

<LBody> Shillingburg HT Jr, Hatch RA, Keenan MP, et al. Impression materials and techniques used for cast restorations in eight states. J Am Dent Assoc. 1980 May;100(5):696-699. doi: 10.14219/jada. archive.1980.0228. </LBody>
</LI>

<LI>
<Link>Full text links </Link>

<Link>CrossRef </Link>

<Link>PubMed </Link>

<Link>Google Scholar </Link>

<Link>Scopus </Link>
</LI>
</L>

<L>
<LI>
<Lbl>10.</Lbl>

<LBody> Morgano SM, Milot P, Ducharme P, et al. Ability of various impression materials to produce duplicate dies from successive impressions. J Prosthet Dent. 1995 Apr;73(4):333-340. doi: 10.1016/s0022-3913(05)80327-0. </LBody>
</LI>

<LI>
<Link>Full text links </Link>

<Link>CrossRef </Link>

<Link>PubMed </Link>

<Link>Google Scholar </Link>

<Link>Scopus </Link>

<Link>WoS </Link>
</LI>
</L>

<LI>
<Lbl>11.</Lbl>

<LBody> Chee W, Jivraj S. Impression techniques for implant dentistry. Br Dent J. 2006 Oct 7;201(7):429-432. doi: 10.1038/sj.bdj.4814118. </LBody>
</LI>
</L>

<P>
<Link>Full text links </Link>

<Link>PubMed </Link>

<Link>Google Scholar </Link>
</P>

<P>Original Articles </P>

<Sect>
<P>35-41 </P>
</Sect>

<P>39 </P>

<Sect/>

<P>Original Articles </P>

<L>
<LI>
<Lbl>12.</Lbl>

<LBody> Conventional Impression-Taking | Thommen Medical [Online]. Accessed May 27, 2023. Available from: 
<Link>https://www.thom</Link>

<Link>menmedical.com/us-en/dental-professionals/products/impres</Link>

<Link>sion-taking/conventional-impression-taking </Link>
</LBody>
</LI>

<Sect>
<L>
<LI>
<Lbl>13.</Lbl>

<LBody> Hamalian TA, Nasr E, Chidiac JJ. Impression materials in fixed prosthodontics: influence of choice on clinical procedure. J Prosthodont. 2011;20(2):153-160. doi: 10.1111/j.1532849X.2010.00673.x. Epub 2011 Feb 1. </LBody>
</LI>

<LI>
<Link>Full text links CrossRef PubMed Google Scholar Scopus WoS </Link>
</LI>
</L>
</Sect>

<LI>
<Lbl>14.</Lbl>

<LBody> Digital impressions or conventional impressions - What's better? [Online]. Accessed May 27, 2023. Available from: 
<Link>https:// </Link>

<Link>www.cayster.com/blog/digital-impressions-or-conventional-im</Link>

<Link>pressions-whats-better </Link>
</LBody>
</LI>

<Sect>
<L>
<LI>
<Lbl>15.</Lbl>

<LBody> Birnbaum NS, Aaronson HB. Dental impressions using 3D digital scanners: virtual becomes reality. Compend Contin Educ Dent. 2008;29(8):494, 496, 498-505. </LBody>
</LI>

<LI>
<Link>PubMed Google Scholar Scopus </Link>
</LI>
</L>
</Sect>

<LI>
<Lbl>16. </Lbl>

<LBody>Traditional vs. Digital impressions [Online]. Accessed Apr. 21, 2023. Available from: 
<Link>https://prodentusa.com/traditional-vs-digi</Link>

<Link>tal-impression-trays/ </Link>
</LBody>
</LI>

<Sect>
<L>
<LI>
<Lbl>17. </Lbl>

<LBody>VR Sastri, Vinny R. Plastics in medical devices: properties, requirements, and applications. William Andrew, eBook ISBN: 9780323851275, 2021. </LBody>
</LI>

<LI>
<Link>Google Scholar </Link>
</LI>
</L>

<L>
<LI>
<Lbl>18. </Lbl>

<LBody>Tolidis K, Tortopidis D, Gerasimou P, et al. Comparison of elastomeric impression materials' thixotropic behavior. Eur J Prosthodont Restor Dent. 2013;21(2):75-78. </LBody>
</LI>

<LI>
<Link>Full text links CrossRef PubMed Google Scholar Scopus WoS </Link>
</LI>
</L>

<L>
<LI>
<Lbl>19.</Lbl>

<LBody> Mandikos MN. Polyvinyl siloxane impression materials: an update on clinical use. Aust Dent J. 1998;43(6):428-434. doi: 10.1111/j.1834-7819.1998.tb00204.x. </LBody>
</LI>

<LI>
<Link>Full text links CrossRef PubMed Google Scholar Scopus WoS </Link>
</LI>
</L>

<L>
<LI>
<Lbl>20.</Lbl>

<LBody> Gomez-Polo M, Celemin A, del Rio J, et al. Influence of technique and pouring time on dimensional stability of polyvinyl siloxane and polyether impressions. Int J Prosthodont. 2012;25(4):353-356. </LBody>
</LI>

<LI>
<Link>PubMed Google Scholar Scopus WoS </Link>
</LI>
</L>

<L>
<LI>
<Lbl>21.</Lbl>

<LBody> Ho W, Lin Seow L, Musawi A. Viscosity effects of polyvinyl siloxane impression materials on the accuracy of the stone die produced. J Clin Transl Res. 2018;4(1):70-74. </LBody>
</LI>

<LI>
<Link>Full text links CrossRef PubMed Google Scholar Scopus </Link>
</LI>
</L>
</Sect>

<L>
<LI>
<Lbl>22.</Lbl>

<LBody> Mojsiewicz-Pieńkowska K, Jamrógiewicz M, Szymkowska K, et al. Direct human contact with siloxanes (silicones) - safety or risk part 1. Characteristics of siloxanes (silicones). Front Pharmacol. 2016;7:132. doi: 10.3389/fphar.2016.00132. </LBody>
</LI>

<Sect>
<LI>
<Link>Full text links CrossRef PubMed Google Scholar WoS </Link>
</LI>
</Sect>
</L>

<Sect>
<LI>
<Lbl>23.</Lbl>

<LBody> Silicone: a guide to production, uses and benefits – SIMTEC [Online]. Accessed Jun. 13, 2023. Available from: 
<Link>https://www. </Link>

<Link>simtec-silicone.com/blogs/how-is-silicone-produced/ </Link>
</LBody>
</LI>
</Sect>

<LI>
<Lbl>24. </Lbl>

<LBody>The many uses of dental impression silicone [Online]. Accessed Apr. 21, 2023.  Available from: 
<Link>https://magazine.zhermack. </Link>

<Link>com/en/laboratory-en/many-uses-of-dental-impression-silicone/ </Link>
</LBody>
</LI>

<LI>
<Lbl>25.</Lbl>

<LBody> Bilir H, Ayguzen C. Comparison of digital and conventional impression methods by preclinical students: efficiency and future expectations. J Int Soc Prev Community Dent. 2020;10(4):402-409. doi: 10.4103/jispcd.JISPCD_330_18. </LBody>
</LI>
</L>

<Sect>
<P>
<Link>Full text links CrossRef PubMed Google Scholar Scopus WoS </Link>
</P>

<L>
<LI>
<Lbl>26.</Lbl>

<LBody> Condensation and addition silicon impression material [Online]. Accessed Jun. 13, 2023. Available from: 
<Link>https://www. </Link>

<Link>juniordentist.com/silicone-impression-material.html </Link>
</LBody>
</LI>

<L>
<LI>
<Lbl>27.</Lbl>

<LBody> Naumovski B, Kapushevska B. Dimensional stability and accuracy of silicone - based impression materials using different impression techniques - a literature review. Pril (Makedon Akad Nauk Umet Odd Med Nauki). 2017;38(2):131-138. doi: 10.1515/ prilozi-2017-0031. </LBody>
</LI>

<LI>
<Link>Full text links CrossRef PubMed Google Scholar </Link>
</LI>
</L>

<L>
<LI>
<Lbl>28.</Lbl>

<LBody> Zare M, Ghomi ER, Venkatraman PD, et al. Silicone-based biomaterials for biomedical applications: antimicrobial strategies and 3D printing technologies. Journal of Applied Polymer Science. 2021;138(38):50969. </LBody>
</LI>

<LI>
<Link>CrossRef Google Scholar Scopus WoS </Link>
</LI>
</L>

<L>
<LI>
<Lbl>29.</Lbl>

<LBody> Razmjoo H, Abdi E, Atashkadi S, et al. Comparative study of two silicone hydrogel contact lenses used as bandage contact lenses after photorefractive keratectomy. Int J Prev Med. 2012;3(10):718-722. </LBody>
</LI>

<LI>
<Link>Full text links PubMed Google Scholar Scopus WoS </Link>
</LI>
</L>

<L>
<LI>
<Lbl>30.</Lbl>

<LBody> Derrien G, Le Menn G. Evaluation of detail reproduction for three die materials by using scanning electron microscopy and two-dimensional profilometry. J Prosthet Dent. 1995;74(1):1-7. doi: 10.1016/s0022-3913(05)80221-5. </LBody>
</LI>

<LI>
<Link>Full text links PubMed Google Scholar Scopus </Link>
</LI>
</L>

<LI>
<Lbl>31. </Lbl>

<LBody>Lin YM. Digitalisation in dentistry: development and practices. The digitization of business in China: exploring the transformation from manufacturing to a digital service hub. 2018:199-217. </LBody>
</LI>

<L>
<LI>
<Lbl>32.</Lbl>

<LBody> Punj A, Fisselier F. Digital dentistry for complete dentures a review of digital dentistry versus conventional approaches to complete dentures. Decis Dent. 26 (2020): 12-20. </LBody>
</LI>

<LI>
<Link>Google Scholar </Link>
</LI>
</L>

<L>
<LI>
<Lbl>33.</Lbl>

<LBody> Unkovskiy A, Wahl E, Huettig F, et al. Multimaterial 3D printing of a definitive silicone auricular prosthesis: an improved technique. J Prosthet Dent. 2021;125(6):946-950. doi: 10.1016/j. prosdent.2020.02.021. </LBody>
</LI>

<LI>
<Link>Full text links CrossRef PubMed Google Scholar Scopus WoS </Link>
</LI>
</L>

<L>
<LI>
<Lbl>34.</Lbl>

<LBody> Konofaos P, Ver Halen JP. Nerve repair by means of tubulization: past, present, future. J Reconstr Microsurg. 2013;29(3):149164. doi: 10.1055/s-0032-1333316. </LBody>
</LI>

<LI>
<Link>Full text links CrossRef PubMed Google Scholar Scopus WoS </Link>
</LI>
</L>

<L>
<LI>
<Lbl>35.</Lbl>

<LBody> Bray A. Essentials of physical medicine and rehabilitation: musculoskeletal disorders, pain, and rehabilitation. Occup Med (Lond). 2017;67(1):80-81. doi: 10.1093/occmed/kqw129. </LBody>
</LI>

<LI>
<Link>Full text links PubMed Scopus </Link>
</LI>
</L>

<LI>
<Lbl>36.</Lbl>

<LBody> Indurent gel – bio link medical surgical equipment &amp; instruments trading [Online]. Accessed Jun. 22, 2023. Available from: </LBody>
</LI>
</L>

<P>
<Link>https://biolinkdubai.com/products/indurent-gel </Link>
</P>

<P>37. StereoMicroscope_2CE-ENBH-1. </P>

<L>
<LI>
<Lbl>38. </Lbl>

<LBody>What is a stereo microscope and how does it work? [Online]. Accessed Jun. 06, 2023. Available from:  
<Link>https://www.micros</Link>

<Link>cope-detective.com/stereo-microscope.html </Link>
</LBody>
</LI>

<LI>
<Lbl>39.</Lbl>

<LBody> Qirici I. Dissertation Diploma, Faculty of Medical Engineering, Politehnica University of Bucharest, 2023a </LBody>
</LI>
</L>

<P>Vlad Gabriel VASILESCU </P>

<P>DDS, PhD, Assistant Professor Prosthetics Technology Department Faculty of Dentistry </P>
</Sect>

<P>&quot;Carol Davila&quot; University of Medicine and Pharmacy CV Bucharest, Romania Vlad Gabriel Vasilescu is a graduate of the &quot;Carol Davila&quot; University of Medicine and Pharmacy. He presents numerous courses completed over the years as well as published works. He specializes in implantology and has submitted research work on the most suitable materials. Vlad Gabriel Vasilescu started his career as a university assistant at the &quot;Carol Davila&quot; University of Medicine and Pharmacy, and in the meantime, he has also completed his doctoral studies. </P>

<Sect><Figure>

<ImageData src="images/Article_11_1-2_2_img_14.jpg"/>
</Figure>
</Sect>

<P>Questions </P>

<P>1. What is the correct order ? </P>

<L>
<LI>
<Lbl>qa.</Lbl>

<LBody> Putty, heavy-bodied, regular, and light-bodied; </LBody>
</LI>

<LI>
<Lbl>qb.</Lbl>

<LBody> Heavy-bodied, putty, regular and light-bodied; </LBody>
</LI>

<LI>
<Lbl>qc.</Lbl>

<LBody> Light-bodied, putty, regular and heavy-bodied; </LBody>
</LI>

<LI>
<Lbl>qd.</Lbl>

<LBody> Regular, putty, heavy-bodied, light-bodied. </LBody>
</LI>
</L>

<P>2. What is the difference between Polyvinyl siloxane materials and condensation silicones? </P>

<L>
<LI>
<Lbl>qa.</Lbl>

<LBody> None, they are the same; </LBody>
</LI>

<LI>
<Lbl>qb.</Lbl>

<LBody> Condensation silicone contains vinyl; </LBody>
</LI>

<LI>
<Lbl>qc. </Lbl>

<LBody>They differ in the terminal ends; </LBody>
</LI>

<LI>
<Lbl>qd.</Lbl>

<LBody> Polyvinyl siloxane materials have a condensation reaction. </LBody>
</LI>
</L>

<P>3. What are the factors by which we choose an impression material? </P>

<L>
<LI>
<Lbl>qa.</Lbl>

<LBody> Money and mental state; </LBody>
</LI>

<LI>
<Lbl>qb. </Lbl>

<LBody>The choice is made based on factors such as accuracy, ease of use, and patient comfort; </LBody>
</LI>

<LI>
<Lbl>qc. </Lbl>

<LBody>The material with the highest polymerization contraction is chosen; </LBody>
</LI>

<LI>
<Lbl>qd. </Lbl>

<LBody>The choice is made strictly based on the patient's preferences. </LBody>
</LI>
</L>

<P>4. What materials were used in the study? </P>

<L>
<LI>
<Lbl>qa.</Lbl>

<LBody> Alginate and reversible hydrocolloids; </LBody>
</LI>

<LI>
<Lbl>qb</Lbl>

<LBody> Thermoplastic materials; </LBody>
</LI>

<LI>
<Lbl>qc.</Lbl>

<LBody> Condensation silicones; </LBody>
</LI>

<LI>
<Lbl>qd.</Lbl>

<LBody> Polyvinyl siloxane with different fluidity. </LBody>
</LI>
</L>
<Figure>

<ImageData src="images/Article_11_1-2_2_img_15.jpg"/>
</Figure>

<P>Original Articles </P>

<P>
<Link>https://admconference.com/ </Link>
</P>

<Sect>
<P>35-41 </P>
</Sect>

<P>41 </P>
</Part>
</TaggedPDF-doc>
